X-RAD160 | Precision - Accurate, Reliable, Repeatable : Precision

Home / Products / X-RAD Range / X-RAD160 XL & IR

The best choice for biological research

A self-contained x-ray system designed to deliver a precise radiation dosage to specimens in a biological or small animal research laboratory. The x-ray tube is used specifically for radiation therapy, having a highly homogenous beam.


Featuring our TouchRad control panel - a multi-user, password protected touch screen interface - the X-RAD160 XL includes a transportable database that can track individual system usage.


Key Features

  • High stability 160kV X-ray tube and generator
  • TouchRad touchscreen control panel
  • Full screen real-time specimen viewing
  • Beam Hardening filter and collimator holder
  • Key operated motorized adjustable specimen shelf
  • Large internal chamber for increased throughput and multiple options

Cabinet Features

  • No additional shielding required
  • Adjustable sample shelf, 15 - 100cm SSD
  • Changeable beam conditioning filter slides
  • Automatic warm-up with Intelligent Tube Conditioning
  • Interior light and camera for sample viewing
  • Cabinet port to introduce small tubing and cables to the chamber area
  • Complies with US and International regulations for Cabinet X-ray systems

Interface Features

  • On-unit, graphical user touch-screen interface
  • Individual user passwords required for system operation
  • Up to 9999 individual accounts can be created
  • Excel database of exposure and user history can be downloaded to a USB drive
  • Programmed exposure settings, database management and user passwords controlled by an administrative Super User

Cabinet Specification

  • Overall dimensions: W 56”(142cm) x D 31”(78cm) x H 76”(193cm)
  • Irradiation Chamber: W 25”(64cm) x D 27”(69cm) x H 42”(106cm)
  • Weight: 3300lbs (1497kg)
  • Power: 230VAC 1Ø, 50A, 50/60Hz

High Voltage Generator

  • Maximum Output Voltage: 160kV
  • Maximum mA: 30

X-ray Tube

  • Standard Max. Output: 160KV / 18.7mA
  • High Powered Max. Output: 160KV / 25mA
  • Max. Power: 4000 W
  • Type: Metal Ceramic, Fixed Anode, Water Cooled
  • Single Focal Spot: 7.5mm (per EN12543)
  • Dual Focal Spot: 1mm, 5.5mm (per EN12543)
  • Inherent Filtration: 0.8mm Be
  • Cooling Pump: Water-Air or Water-Water models available

Dose Output

  • Raw Beam: ~60 Gy/min at 160kV, 18.7mA, 30cm SSD
  • Filtered Beam: ~5.5 Gy/min at 160kV, 18.7mA, 30cm SSD (Filter = 2mm Al)
  • High Powered: ~7.3 Gy/min at 160kV, 25mA, 30cm SSD (Filter = 2mm Al)

Operators Control

  • KV Setting + Display Accuracy: 5kV – 160kV in 0.1kV increments
  • mA Setting + Display Accuracy: 0.5mA - 30mA in 0.01mA increments
  • Settings Accuracy: < 1%
  • Exposure Timer: 1 - 99999 seconds
  • Programmable Settings: 1000’s of locations to recall exposure parameters

Options

  • Programmable Motorized Rotating Shelf
  • Environmental Chamber with O2, CO2 and heating control
  • Planetary Turntable for even dose distribution for up to 6 multiwell plates at a time
  • TouchRad Dose Measurement and Control System
  • Adjustable Light Illuminated X-ray Collimator

The economical choice for high throughput cell irradiation

A compact cabinet x-ray irradiator designed for superficial irradiation studies, and ideal for delivering high doses to cell and tissue cultures.


With an easy-to-use operator interface, it offers the greatest amount of flexibility for performing high and low dose exposures over a broad range of settings.


Key Features

  • Small footprint
  • High stability 160kV X-ray tube and generator
  • Full screen real-time specimen viewing
  • Beam hardening filter and collimator holder
  • Fixed beam limiting apertures
  • Motorized turntable
  • Optional key operated motorized, rotating specimen shelf

Cabinet Features

  • No additional shielding required
  • Adjustable sample shelf, 10 - 100cm SSD
  • Changeable beam conditioning filter slides
  • Automatic warm-up
  • Cabinet port to introduce small tubing and cables to the chamber area
  • Complies with US and International regulations for Cabinet X-ray systems

Cabinet Specification

  • Overall dimensions: W 30”(75cm) x D 29”(73cm) x H 62”(157cm)
  • Irradiation Chamber: W 26”(65cm) x D 26”(65cm) x H 42”(106m)
  • Weight: 1900lbs (862kg)
  • Power: 1N PE 208-230, 50/60Hz, 8KVA

High Voltage Generator

  • Maximum Output Voltage: 160kV
  • Maximum mA: 45

Dose Output

  • Raw Beam: >60 Gy/min at 160kV, 19mA, 30cm SSD
  • Filtered Beam: >6.5 Gy/min at 160kV, 19mA, 30cm SSD (Filter = 2mm Al)

X-ray Tube

  • Max. Potential: 160kV
  • Max. Power: 3000 W (higher power option available)
  • Type: Metal Ceramic, Fixed Anode, Water Cooled
  • Focal Spot: 7.5mm (per EN12543)
  • Inherent Filtration: 0.8mm Be
  • Cooling Pump: Water-Air

Operators Control

  • KV Setting + Display Accuracy: 7.5kV – 160kV in 0.1kV increments
  • mA Setting + Display Accuracy: 0.5mA - 45mA in 0.01mA increments
  • Settings Accuracy: < 1%
  • Exposure Timer: 2 - 600 seconds, or 10 - 99.9 minutes, or continuous
  • Programmable Settings: 500 locations to recall exposure parameters

Options

  • Programmable Motorized Rotating Shelf
  • Environmental Chamber with O2, CO2 and heating control
  • Beam Conditioning Filter
  • TouchRad Dose Measurement and Control System
  • Adjustable Light Illuminated X-ray Collimator